Choosing the LAN cable – Network – Ethernet

Italiana Conduttori Srl, equipped with the latest design machinery for the production of LAN cables, as well as control and testing instrumentation, produces the entire range of data transmission cables under the CAVEL brand: Cat. 5e, 6 and 6A, both shielded and unshielded, and Cat. 7 and 7A, both shielded.

LAN cables specially designed for greater flexibility (labeled with the acronym LANF), as well as special data transmission cables developed to specific client requirements, are also available.

LAN cables (an acronym for Local Area Network, also called Ethernet cables) are the means by which data is transmitted within a local area network, i.e. an integrated computer system consisting of shared computers and devices, such as those within a home, a business establishment, or a building complex.

Differences and characteristics of LAN/Ethernet cables

LAN cables are made up of four twisted pairs that are subsequently stranded together. The pairs have different twist pitches from each other in order to reduce interference between them, known as crosstalk (often abbreviated as NEXT, Near End Cross Talk).

The main regulations governing the standard parameters to which LAN cables must adhere are:

  • ISO 11801 (International Organization for Standardization)
  • EN 50288 (European Standard)
  • EN 50173 (European Standard)
  • IEC 61156 (International Electrotechnical Commission)
  • EIA-TIA 568 (Electronic Industries Association / Telecommunications Industry Association)

The Cavel LAN cable range

Cat. 5e cables

Unshielded and shielded versions. The standard LAN cable for most installations.

Cat. 6 and Cat. 6A cables

Unshielded and shielded versions, up to 500 MHz with Cat. 6A for 10 Gigabit Ethernet.

Cat. 7 cables

Shielded S/FTP cables up to 600 MHz for 10GBASE-T networks.

Cavel Cat. 7A LAN cable

Cat. 7A cables

Shielded cables up to 1000 MHz and beyond, for data centers and enterprise networks.

Types of shielding

The shielding of cables is necessary to protect the transmission of signals from external electromagnetic interference that could impair their quality. Shielding is generally made from:

  1. aluminum foils;
  2. aluminum foils and tinned copper braid,

which wrap the twisted pairs individually or overall. For high-frequency cable categories, aluminum foils that individually cover the pairs (Pairs in Metal Foil, PiMF) are also used, in order to improve both the overall effectiveness of the shielding and the NEXT values (interference between pairs).

The acronyms initially used to denote shielding types were:

  • UTP (Unshielded Twisted Pair): unshielded cable.
  • FTP or STP (Foiled or Shielded Twisted Pair): shielded cable with aluminum foil (Foiled) or tinned copper braid (Shielded).

As technologies advanced and cable performance improved, further differentiations were introduced, since the individual pairs of higher category cables (Cat. 6A and above) can also be shielded, mainly to reduce crosstalk. The following acronyms indicate the presence or absence of shielding overall and on the individual pairs:

CodeDescription
U/UTPUnshielded cable, with no shielding either overall or for individual pairs
F/UTPOverall shielding only, with a foil wrapping around the 4 twisted pairs
U/FTPShielding only on the individual pairs
F/FTPOverall foil shield, plus foils around the individual pairs
S/FTPOverall braid shield, plus foils around the individual pairs
SF/UTPDouble overall shield (braid and foil), individual pairs unshielded
SF/FTPDouble overall shield (braid and foil), plus foil-shielded individual pairs

How to choose the network cable – Ethernet cable – LAN cable

Category (EIA/TIA)FrequencyStandardISO/IEC 11801 classEthernet applications and max. cable length
Cat. 5e UTP / FTP1–100 MHzEN 50288-3-1 (UTP)
EN 50288-2-1 (FTP)
Class D100 m: 10BASE-T, 100BASE-TX, 1000BASE-T, 2.5GBASE-T
The standard LAN cable
Cat. 6 UTP / FTP1–250 MHzEN 50288-6-1 (UTP)
EN 50288-5-1 (FTP)
Class E100 m: 10BASE-T, 100BASE-TX, 1000BASE-T, 2.5GBASE-T, 5GBASE-T
55 m: 10GBASE-T
Improved signal-to-noise ratio
Cat. 6A UTP / FTP1–500 MHz—Class EA—
Cat. 7 (FTP)1–600 MHzEN 50288-4-1Class F100 m: 10GBASE-T
Cat. 7A (FTP)1–1000 MHzEN 50288-9-1Class FA50 m: 40G Ethernet
15 m: 100G Ethernet
Best-in-class cable for enterprise applications

Cheapest, best performing or most recommended? Compare the Cavel LAN cables by price, performance and typical use to find the right one for your project.